C 200 Entry Manual model IKA

 

 
Manual ( teaching mode): ignition and end of the measurement will be done by the operator himself;
the temperature increase will be indicated at the display each minute. 

All calculations have to be done manually. 
At the other three modes ignition and calculation of the gross calorific value will be done automatically. 
The gross calorific value will be shown on the display.
Acid corrections and calculations of the net calorific value have to be done manually. 


The modes have different measuring times: 
Isoperibolic: approx: 17 min. 
Dynamic : approx. 8 min 
Manual : approx. 17 min (depend on the operator) 
Time controlled : 14 min 


The decomposition vessel can be equiped in to use an combustible crucibles C 14 
(accessory C 5010.4 attachment is neessary) 

User-friendly software C 5040 Calwin
for controlling the calorimeter and administration of measuring data (asseccory). 

Transfer of the datas to Excel or Word are possible 
Up to eight IKA measuring cells can be controlled by a single PC,
using a multiserial plug in card PCI 8.2 (accessory)