en-USel-GR

Lab Pharmaceutical pH meters

 

  pH Meter Lab 860

Direct data transfer either conventional through RS 232 or modern via USB
Both PC-interfaces are integrated in the Lab 860 – no adapter required.

Digital documentation 
good laboratory practice – taken literally
The calibration protocols and up to 800 data records including time and identification can be called up.

New: 5-point calibration
for very exact pH-measurements.
         
         
 
 

  ProLab 1000

Exact measurements
with a measuring range from -2.000 to +20.000 pH and an accuracy of 0.003 pH, 
the automated calibration with up to 5 points and the automatic buffer recognition out of 22 buffer sets.

Electrodes and user identification – safety
Every stored measuring result shows the used ID-electrode and the user. 
The calibration data are stored in the ID-sensor. 
Therefore even when using multiple ID-electrodes on the same meter, 
the correct calibration data is always chosen automatically.

Documentation according to GLP
Protocols for the last ten calibrations 
and all measuring results with time and ID are available in up to 1,500 storages places.

Direct data transmission
Whether conventional via RS 232 or modern via USB
both PC interfaces are integrated in the ProLab 1000.

Dead stop function
The integrated dead stop function 
widens the field of application for manual titration jobs (e.g. wine and food industry).

NEW: With ISE-measurement
With a measuring range from 0.000 to 999,999 mg/l and a 2 to 5-point calibration with standards from 0.000 to 500,000 mg/l.
 
         
 

  ProLab 2000

One for all – pH, ISE, oxygen and conductivity with only one instrument
Up to four parameters can be measured and displayed at the same time. 
The selection of the parameters is menu-driven.
 
Electrode and user identification – highest safety
Every stored measuring result shows the used ID-electrode and the user. 
The calibration data are stored in the ID-sensor. 
Therefore even when using multiple ID-electrodes on the same meter, 
the correct calibration data is always always chosen automatically.

Professional measurement
With a measuring range from -2.000 to +20.000 pH and an accuracy of 0.003 pH, 
the automated calibration with up to 5 points (pH and ISE) and the automatic buffer recognition out of 22 buffer sets.

The new combined sensor LFOX 1400 ID is included
A sensor with ID function for three parameters: conductivity, dissolved oxygen and temperature. 
The oxygen module can be easily removed and works according to the time-proven and reliable galvanic principle. 
Immediately ready for use, little maintenance required.